Dvl improves stove performance by maintaining high flue gas temperatures for a strong steady draft.
Triple wall stove pipe clearance.
Chimney pipe also is made in two types double wall and triple wall.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
Stove pipe is made in single and double wall versions.
As listed where shown in the table above means that the acceptable fire clearance distances for those chimney types must match or comply with the manufacturer s instructions.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Ul standard 103 requires pipe capable of safety operating with an internal temperature of 1 000.
Our class a tiple wall chimney systems stay cool on the outside while providing a hot draft on the inside.
Those clearance spacings are normally found in at least two locations.
The chimney could very well be ht or class a generic not a fireplace chimney but most of us have only seen such chimney with 2 clearances.
Triple wall class a pipe is the preferred solution for homeowners installing their own system due to its increased margin of safety.
2 clearance to combustibles.
Triple wall all fuel chimney for use with wood stoves fireplaces furnaces boilers stoves ranges water heaters or other appliances fueled by wood oil coal or gas.
Listing double and triple wall insulated pipe is listed as class a vent pipe and must meet either ul standard 103 or 103ht.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
All stove chimney pipe is chosen and classified by the inside diameter.
To 6 in the closest clearance to a wall of any connector pipe.
Class a triple wall chimney systems are designed for easy installation feature a fire safe design to protect both the chimney the building.
This boosts stove efficiency by exhausting hot flue gases easily and efficiently.
Notes to the metal chimney fire clearance table above.
018 aluminized steel intermediate liner.
The installation instructions for the specific flue vent connector or metal.
016 430 stainless.
A class a chimney pipe requires less clearance than a single or double wall stovepipe which is only intended for use within the same room as the stove.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
So 1 stop using the thing until you solve this.
Dvl s double wall air insulated design reduces clearances to combustibles from 18 in.
Ul listed to ul 103ht mh7399 please note.
Materials and construction 016 430 stainless steel outer wall or 018 galvanized steel outer wall.